N-65VSat Operation: For spot-check or continuous monitoring Display: Oxygen saturation, pulse rate, vertical bar graph pulse amplitude indicator/battery meter, pulse
search indicator, low battery indicator, alarm silence, data in sensor, sensor disconnect, print Display Range:
SpO2: 0% to 100% Pulse rate: 20 to 250 bpm Printing: Via a cable-free infrared link Power
Requirements: 6 V supplied by four AA-size alkaline batteries Battery Life: 19 hours typical
(40 hours lithium) Environmental Altitude: -1,254 ft 9,882 ft (-382 m to 3,012 m) Relative
Humidity: 15% to 95% noncondensing Temperature: Storage: -20°C to 70°C Operating:
5°C to 55°C Weight: 0.65lbs (0.29kg) Dimensions: 2.8" x 6.2"
x 1.4" (7.3 x 15.8 x 3.5 cm) Standards: N60601-1-2 (CISPR 11, Class B) EN60601-1 (IEC 601-1) (Class:
Internally Powered, Type BF) CS114, RS101, and CAN/CSA 601.1 (Class: Internally Powered, Type BF) CAN/CSA NRTL/C
N-560VSat Operation: For spot-check
or continuous monitoring Display: High quality LED display Oxygen saturation, pulse rate,
alarm status, battery status, sensor status LEDs turn red during alarm conditions Pulse amplitude indicator-10 segment
LED
Display Range: SpO2: 1% to 100% Pulse rate: 20 to 250 bpm Visual indicators:
Pulse search, audible alarms off, artifact indicator, low battery and battery charging. Alarms: (Audible
+ visual) o High/low saturation o Pulse rate o Low battery Output: EIA-232 and
RS-422 digital output from serial port Oxinet communications output protocol Nurse call capability Power
Requirements: Instrument: 100 to 240 VAC, 18-26 VA Fuse Battery: NiMH, 8 hours Environmental
Altitude: -1,254 ft 18,288 ft Operating Humidity: 15% to 95% noncondensing Temperature:
Storage: -20°C to 70°C Operating: 10°C to 45°C Dimensions: 2.4 in. H x 7.9
in. W x 4.7 in. D (6.0 cm x 20.0 cm x 12.0 cm) Weight: 2.4 Ib/1.3 kg Standards:
EN/IEC601-1-2 . CSA601.1 . UL2601-1 . IPX1 Approved, EN865, Class B equipment, EN55011
N-85
Operation: o For mechanically ventilated and spontaneously breathing patients.
o For use on intubated and nonintubated patients. Low sample flow rate of 50 ml/min allows monitoring on the widest
range of patients o Monitoring even in challenging high-humidity environments. o Capnographic waveforms and trends.
Performance: Capnograph: Display range: 0 to 99 mmHg Sampling rate: 50 +- 7.5 ml/min Respiration rate: 0 to 150 breaths/minute Pulse Oximeter: Display range: 0% to 100% Pulse rate: 20 to 250
BPM Displayed parameters: N-85: CO2 & plethysmographic waveforms, ETCO2, SpO2, pulse rate,
respiration rate, trend data NPB-70: CO2 waveforms, ETCO2, respiration rate, trend data Display:
Graphic LCD display (128 x 64 dots) with LED backlight (contrast and backlight control); two numeric fields, 3 digits each,
using 7-segment LED; two-color LED alarm bar Alarms: Adjustable alarm limits for all parameters; audio
level as defined in ISO 9703-2 standard Communication Interface: RS-232 interface @ 9600 baud; full duplex serial interface
via RJ - 45 connector Power Requirements: AC input of 100 to 230 VAC @ 60/50 Hz Battery: Rechargeable NiMH; supplies
power between 4 to 7 hours (depending on power management). Fully recharges in approximately 4.5 hours Temperature: Storage: -31°F to 158°F (-35°C to 70°C) Operating: 32°F to 113°F (O°C to 45°C) Altitude:
-1,250 It to 15,000 ft (-381 m to 4,572 m) Humidity: 10% to 95% noncondensing Dimensions:
8.11 in H x 346 in W x 206 in D (206 mm x 88 mm x 53 mm) Weight: N-85: 1.87 Ib (850 g) NPB-70:
1.66 Ib (750 g) Standards: IEC 601-1/EN 60601-1, EN60601-2 second edition, EN 864, EN 865, UL 2601-1,
EN 475, EN 55011-Class B-Group 1, CSA C22.2 No. 601.1-M90 Environmental: Shock test IEC 68-2-27 Sinusoidal
vibration test IEC 68-2-6 Random vibration wide band test IEC 68-2-34 Drop test MIL-STD-810E, method 516.4-11
|